Maximum frequency: 25.0 to 400.0 Hz variable
Starting frequency: 0.1 to 60.0 Hz variable
Output frequency accuracy(Stability)
Analog setting: ±2% of max freq. (at 25°C),temperature drift: ±0.2% of max freq. (at 25±10°C)
Keypad setting: ±0.01% of max freq. (at 25°C),temperature drift: ±0.01% of max freq. (at 25±10°C)
Voltage/frequency characteristics
200 V class series: Possible to set output voltage at base frequency and at maximum output frequency (80 to 240 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 240 V) and frequency (0 to 400 Hz) can be set.
400 V class series: Possible to set output voltage at base frequency and at maximum output frequency (160 to 500 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 500 V) and frequency (0 to 400 Hz) can be set.
Starting torque: 150% or more (Running at 3 Hz, with auto torque boost active)
Timer operation: Operate and stop by the time set with keypad
Current limit: Hardware current limiting is used avoiding over current tripping of the inverter, when impact load change or momentary power failure that can be responded software current limiting

标签:

描述

Specifications of Fuji FRN22G1S-4C Inverter Drive FRENIC-Mega Series
Series: FRENIC-Mega
Maximum frequency: 25.0 to 400.0 Hz variable
Starting frequency: 0.1 to 60.0 Hz variable
Output frequency accuracy(Stability)
Analog setting: ±2% of max freq. (at 25°C),temperature drift: ±0.2% of max freq. (at 25±10°C)
Keypad setting: ±0.01% of max freq. (at 25°C),temperature drift: ±0.01% of max freq. (at 25±10°C)
Voltage/frequency characteristics
200 V class series: Possible to set output voltage at base frequency and at maximum output frequency (80 to 240 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 240 V) and frequency (0 to 400 Hz) can be set.
400 V class series: Possible to set output voltage at base frequency and at maximum output frequency (160 to 500 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 500 V) and frequency (0 to 400 Hz) can be set.
Starting torque: 150% or more (Running at 3 Hz, with auto torque boost active)
Timer operation: Operate and stop by the time set with keypad
Current limit: Hardware current limiting is used avoiding over current tripping of the inverter, when impact load change or momentary power failure that can be responded software current limiting

富士FRN22G1S-4C变频器驱动FRENIC-Mega系列的规格
系列:FRENIC-Mega
最大频率:25.0至400.0 Hz变量
启动频率:0.1至60.0 Hz变量
输出频率精度(稳定)
模拟设置:最大频率的±2%(25°C),温度漂移:最大频率的±0.2%(25±10°C)
键盘设置:最大频率的±0.01%(25°C),温度漂移:最大频率的±0.01%(25±10°C)
电压/频率特性
200v级系列:可在基本频率和最大输出频率(80 ~ 240v)设置输出电压,AVR控制*1可开可关。非线性V/f *1设置(2点):可设置自由电压(0 ~ 240v)和频率(0 ~ 400hz)。
400v级系列:可设置输出电压在基本频率和最大输出频率(160 ~ 500v), AVR控制*1可打开或关闭。非线性V/f *1设置(2点):可设置自由电压(0 ~ 500v)和频率(0 ~ 400hz)。
启动扭矩:150%或更多(以3hz运行,与自动转矩升压活动)
计时器操作:按键盘设定的时间进行操作和停止
限流:硬件限流用于避免冲击负载变化或瞬时断电时逆变器过电流跳闸,可通过软件限流响应

Specifications of Fuji FRN22G1S-4C Inverter Drive FRENIC-Mega Series
Series: FRENIC-Mega
Maximum frequency: 25.0 to 400.0 Hz variable
Starting frequency: 0.1 to 60.0 Hz variable
Output frequency accuracy(Stability)
Analog setting: ±2% of max freq. (at 25°C),temperature drift: ±0.2% of max freq. (at 25±10°C)
Keypad setting: ±0.01% of max freq. (at 25°C),temperature drift: ±0.01% of max freq. (at 25±10°C)
Voltage/frequency characteristics
200 V class series: Possible to set output voltage at base frequency and at maximum output frequency (80 to 240 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 240 V) and frequency (0 to 400 Hz) can be set.
400 V class series: Possible to set output voltage at base frequency and at maximum output frequency (160 to 500 V). The AVR control *1 can be turned ON or OFF. Non-linear V/f *1 setting (2 points): Free voltage (0 to 500 V) and frequency (0 to 400 Hz) can be set.
Starting torque: 150% or more (Running at 3 Hz, with auto torque boost active)
Timer operation: Operate and stop by the time set with keypad
Current limit: Hardware current limiting is used avoiding over current tripping of the inverter, when impact load change or momentary power failure that can be responded software current limiting